Skip to content

Date 1984

Publication type Report

AN ELECTROCHEMICAL TECHNIQUE FOR MEASUREMENTS OF TIME OF WETNES.

Publication details

Publication type: Research report

Series: NILU TR, 17/84

Publisher: NILU

Summary:

An electrochemical technique for measurement of time of wetness (TOW) is described. The method is based upon measurement of the current generated in electrolytic Cu/Cu celles at the time of atmospheric exposure. When this current exceeds a "wet" threshold value TOW is recorded by the instrument. The instrument which allows for recording of 6 sensors simultaneously is fully automatic with computerized data handling and analyses (NILU-WETCORR).